Encoding

Every instruction is one byte, and three different field layouts share those eight bits:

    register form     A A B B o o o o      rA = instr[7:6]   rB = instr[5:4]
                      7 6 5 4 3 2 1 0      op = instr[3:0]

    branch form       d d d d o o o o      d  = instr[7:4], 4-bit SIGNED
                      7 6 5 4 3 2 1 0      op = instr[3:0]

    SHIFT             A A D S S 0 1 1      D  = instr[5]: 1 = left, 0 = right
                      7 6 5 4 3 2 1 0      SS = instr[4:3], the amount, 0..3

    ORI               i i i i i 1 1 1      i  = instr[7:3], a 5-bit immediate
                      7 6 5 4 3 2 1 0

SHIFT and ORI are selected by their low three bits, while every other instruction is selected by the full low nibble.

The table

rA is both a source and the destination. The flags are N, which is bit 7 of the result, and Z, which is set when the whole result was zero. A dash in the flags column means the instruction leaves both flags exactly as they were.

op byte mnemonic what it does flags cycles assembler
0000 0x?0 LOAD rA, rB rA <- mem[rB]; rB is the pointer — 4 LOAD(1, 2)
0001 0x?1 JMP d PC <- PC+1+d, always — 3 JMP(-3)
0010 0x?2 STORE rA, rB mem[rB] <- rA; same order as LOAD — 3 STORE(1, 3)
0011 0x?3 SHL rA, n / SHR rA, n rA <- rA << n or rA >> n, n in 0..3 N Z 4 SHL(0, 3)
0100 0x?4 ADD rA, rB rA <- rA + rB, wraps at 8 bits N Z 4 ADD(1, 0)
0101 0x?5 BPZ d if N == 0: PC <- PC+1+d — 3 BPZ(2)
0110 0x?6 SUB rA, rB rA <- rA - rB, wraps at 8 bits N Z 4 SUB(1, 2)
0111 0x?7 ORI imm5 r0 <- r0 \| imm5; the destination is always r0 N Z 5 ORI(5)
1000 0x?8 NAND rA, rB rA <- ~(rA & rB) N Z 4 NAND(1, 1)
1001 0x?9 BNZ d if Z == 0: PC <- PC+1+d — 3 BNZ(-3)
1010 0x?A BZ d if Z == 1: PC <- PC+1+d — 3 BZ(1)
1011 0x?B (SHIFT again) the second encoding of SHIFT N Z 4
1100 0x?C (unimplemented) PC+1 and does nothing else — 4 UNIMP()
1101 0x?D (unimplemented) PC+1 and does nothing else — 4
1110 0x?E (unimplemented) PC+1 and does nothing else — 4
1111 0x?F (ORI again) the second encoding of ORI N Z 5

The ? stands for whatever the register or displacement fields happen to hold. The byte 0x44 is ADD r1, r0 and the byte 0x04 is ADD r0, r0, but both are ADD, because the low nibble is 4 in each.

All 256 bytes

There are no illegal encodings, because every byte decodes to something, and no two opcodes collide. We checked this by single-stepping all 256 instruction bytes and classifying each one by its cycle count, done, PC delta, register write and memory write:

encodings which
the nine 4-bit opcodes 16 each, 144 total 0x?0 0x?1 0x?2 0x?4 0x?5 0x?6 0x?8 0x?9 0x?A
SHIFT 32 0x?3 and 0x?B
ORI 32 0x?7 and 0x?F
unimplemented 48 0x?C 0x?D 0x?E
256

Because SHIFT and ORI are chosen by only three bits, each of them owns two low nibbles. Nothing else is assigned to 0x?B or 0x?F, so the aliasing does no harm. It does mean, though, that the byte 0xF1 is a JMP while 0xFF is an ORI, and the two differ in one bit that most people don’t look at.

Disassembling a byte from the command line

The assembler also works as a disassembler. When a test fails and a log line shows you a hex byte, this is the quickest way to find out which instruction it was:

cd labs/common
python3 simproc_asm.py 0x2F 0x44 0xD9
0x2F   ORI   5
0x44   ADD   r1, r0
0xD9   BNZ   -3

The script imports nothing and needs no simulator, and it will decode as many bytes as you give it.

Here are some bytes worth learning to recognise on sight:

byte
0x0C (unimplemented) what the harness fills unwritten RAM with
0xF1 JMP -1 the parking loop, which is a jump to itself
0x06 SUB r0, r0 the idiom for “clear r0”
0x2F ORI 5
0x3B SHL r0, 3
0x8B SHR r2, 1 note the low nibble, B, which is SHIFT’s second encoding

Branch displacements

The PC is incremented during CYCLE_1, before the branch computes its target in CYCLE_3, so the displacement is measured from the instruction after the branch:

\[\text{target} = (\text{address of the branch}) + 1 + d\]

JMP(0) falls through to the next instruction
JMP(1) skips one instruction
JMP(-1) an infinite loop on itself, which is the parking idiom
range -8 to +7, and nothing outside it

The field is four bits wide and signed. If you branch to a label further away than that, the assembler stops with an error rather than quietly wrapping the displacement:

ValueError: line 12: 'BNZ loop': 'loop' is -11 instructions away and a SimProc
branch only reaches -8..+7. Move the label closer, or JMP to a JMP.

Flags

set N and Z leave them alone
ADD SUB NAND SHL SHR ORI LOAD STORE JMP BZ BNZ BPZ

N is bit 7 of the result, and Z means the whole 8-bit result was zero. There is no carry flag and no overflow flag, so arithmetic wraps without telling you.

The branches leave the flags alone by specification, not by accident, and that is what lets you compare once and then branch on the result twice:

        SUB   r1, r1        # r1 = 0  ->  Z = 1
        BZ    taken         # taken
        ORI   16            # skipped
taken:  BNZ   wrong         # must NOT be taken: Z is still 1

Idioms

This instruction set lacks several things you’re used to, and each gap has a standard workaround. Think of these as the only way to write each operation on SimProc rather than as tricks.

you want you write why
clear rX SUB rX, rX there is no MOV and no CLR
NOT rX NAND rX, rX there is no NOT
compare rA against rB SUB rA, rB there is no CMP, and the compare destroys rA
stop the program JMP -1 there is no HALT instruction
a constant in r0 SUB r0, r0, then ORI ORI only sets bits
a constant larger than 31 ORI the high bits, SHL, ORI the low bits the immediate is 5 bits
a constant in r1/r2/r3 build it in r0, then SUB rX, rX ; ADD rX, r0 ORI only writes r0

Every row in that table is also an entry in the bug catalogue. SUB rX, rX is symmetric, so it gives the right answer even on a core whose subtract is backwards, and NAND rX, rX is the one operand pattern for which NAND and NOR agree. The idiom a programmer reaches for first is the one that hides the bug. Where bugs hide covers this at length.

Building a constant by hand is easy to get wrong, so the assembler has a helper that does it for you:

>>> from simproc_asm import set_reg, listing
>>> print(listing(set_reg(1, 0xB7)))
  00: 06   SUB   r0, r0
  01: B7   ORI   22
  02: 3B   SHL   r0, 3
  03: 3F   ORI   7
  04: 56   SUB   r1, r1
  05: 44   ADD   r1, r0

The helper always emits four instructions for r0 and six for r1–r3, so the cycle count stays predictable. It does clobber N and Z, because SUB, ORI and SHL all set flags, so set your registers up before a compare, never between the compare and the branch.

Cycle counts

The core is not pipelined and nothing is speculative, so a program’s cycle count is the sum of the cycle counts of its instructions, and you can check it by hand.

instruction cycles
ORI 5 CYCLE_1…CYCLE_5, writes r0 in CYCLE_5
ADD SUB NAND SHL SHR LOAD 4 write-back in CYCLE_4
STORE JMP BZ BNZ BPZ 3 retires in CYCLE_3
0xC 0xD 0xE 4 and no done pulse; see below

A branch costs 3 cycles whether or not it is taken.

Unimplemented opcodes: four cycles

These opcodes match no clause in CYCLE_3, so the FSM takes its default exit to IDLE, spends a cycle there, and is sent back to CYCLE_1 by run, which is still asserted. When we measured four filler bytes in a row, they took 16 clock cycles, produced 0 done pulses, and had halt high on 4 of the 16.

That last figure matters. 0x0C is what sp.start() fills unwritten RAM with, so a program that runs off its own end makes the halt pin blink. “halt must stay low while run is asserted” is an assertion Lab 05 asks you to write, so if it fires in that situation, your test is working correctly on a machine that is behaving as designed.

golden.py said three cycles until somebody measured it, and The golden model tells that story.

Writing a program

There are three ways to write a program, shown here from least to most readable:

prog = [0x2F, 0x44, 0xD9]              # ... which of these is the loop?
from simproc_asm import ORI, ADD, STORE
prog = [ORI(5), ADD(1, 0), STORE(1, 2)]
from simproc_asm import assemble
prog = assemble("""
        ORI   5              # r0 = 5
        ADD   r1, r0         # r1 = 5
loop:   SUB   r1, r0         # r1 -= 5
        BNZ   loop           # ... until it hits zero
        STORE r1, r2
""")

The text front end works out the branch displacements for you. That is the only reason to use it, but it’s a good one, because almost everybody measures a displacement from the wrong place the first time.

listing(prog) prints a dump with the address, hex byte and mnemonic of each instruction. If you put it in your failure messages, it will save you twenty minutes when a test fails:

  00: 06   SUB   r0, r0
  01: 0F   ORI   1
  02: A6   SUB   r2, r2

Traps

Each of these has cost somebody an evening.

  1. ORI ORs its immediate into r0 and never clears any bits. Do SUB r0, r0 first, or you get the OR of everything r0 has ever held.
  2. ORI always writes r0. There is no register field to get wrong, and no way to make it write anything else.
  3. Shift amounts are 0–3. SHL(0, 4) raises an error rather than quietly truncating the amount: shift amount 4 does not fit in 2 bits. SimProc shifts by 0, 1, 2 or 3 — to shift by 4, use two instructions.
  4. The branch range is -8 to +7, measured from the instruction after the branch.
  5. Arithmetic wraps without any warning. 200 + 60 is 4, and there is no carry flag to check.
  6. Addresses above 63 don’t exist. A read from one returns X and a write to one is dropped, and neither of them aliases into low memory.
  7. LOAD rA, rB and STORE rA, rB take the data register first and the pointer second. The order is the same for both, and it is the opposite of what many readers expect.
  8. SUB is your compare, and it destroys rA. If you need the value afterwards, copy it first, and remember that a copy costs two instructions and overwrites both flags.